Use this command to temporarily change the excitation supplied to the loadcell.
This method is intended to use only for diagnostic purposes,such as when using a DC milli-voltmeter.
Note ♦ |
Changing the excitation mode may add an offset to the A/D measurements. Therefore, the system should be calibrated using the same excitation mode the loadcell will work with. |
♦ |
In general, the working excitation mode should be set via Hardware Configuration. |
♦ |
The Change Excitation command overrides the hardware configuration excitation setting until the next system reset / power-up. |
♦ |
Changing excitation mode may cause a momentary conversions-break (about 300msec) due to filter reset. |
Command parameters
SI 141 |
Determines which excitation mode, the Loadcell number, and the DIN rail location of the module. Four digits are stored in SI 141.
|
||||||||
SI 142 |
MI address; this MI will contain the Command Status indication |
||||||||
SI 140 |
Command number:#8270 |