You can force the controller to boot up into Bootstrap or Stop mode (hard reset) by turning on the power supply while pressing specific keypad keys.
You can also erase all of the PLC's data, including the OS, via Info Mode.
|
Mode |
Features |
Possible Actions |
V350/V430/290/530/570/V1040/Samba |
|
Bootstrap |
|
-Via Vision Communication PC Settings, you can:
- (Enhanced only) Enter Boot Info Mode |
|
|
Stop (O/S) |
As in Bootstrap, but Info mode can be entered. |
As above, but all Info mode actions are supported. Exit Stop Mode by entering Information Mode, and then selecting System>Working Mode> Reset. |
Note ♦ Visions embedded with Bootstrap versions previous to 2.00 cannot enter Stop mode. |
|
Bootstrap, default LCD contrast |
|
Contrast range is 0-100, this option automatically sets Contrast to 50. |
|
|
Stop (O/S, |
|
Contrast range is 0-100, this option sets Contrast to 50. |
|
|
Mode |
Features |
Possible Actions |
EX-RC1 |
V120/130 |
V230/260 |
V280 |
|
Bootstrap |
|
-Via Vision Communication PC Settings, you can:
- (Enhanced only) Enter Boot Info Mode |
Move all DIP switches to 1 |
<I> + |
<I> + |
<I> + |
|
Stop (O/S) |
As in Bootstrap, but Info mode can be entered. |
As above, but all Info mode actions are supported. Exit Stop Mode by entering Information Mode, and then selecting System>Working Mode> Reset. |
Move all DIP switches to 0 |
<I> |
<I> |
<I> |
|
Bootstrap, default LCD contrast |
|
Contrast range is 0-100, this option automatically sets Contrast to 50. |
|
<I> + |
|
<I> + |
|
Stop (O/S, |
|
Contrast range is 0-100, this option sets Contrast to 50. |
|
<I> + |
|
<I> + |