Note that devices used in conjunction with Unitronics controllers must be calibrated according to the available range. Below, Range refers to the value contained by the register that is linked to the I/O in Hardware Configuration.
Analog output values are contained in the register that you link to the output in Hardware Configuration.
Model number |
Resolution |
Range |
V200-18-E1
(Snap-in I/O module) M90 controllers (analog input) M91-19-R1, M91-19-R2, R2C |
10
bit (0-10V, 0-20mA, |
0-1023,
1024 units (except at 4-20mA) |
V120-12-UN2 M90-19-UN2 |
14 bit (0-10V, 4-20mA) Temperature ranges appear in the following table |
0-16383,
16384 units (except at 4-20mA) |
IO-AI4-AO Input Output |
12 bit (0-10V,
0-20mA, 12
bit +sign (±10V, 0-20mA, |
0-4095,
4096 units (except at4-20mA) |
Model number |
Type |
Input ranges |
Range |
V120-12-UN2 M90-19-UN2 |
mV B E J K N R S T |
-5 to 56mV 200 to 1820° C (300 to 3276° F) -200 to 750° C (-328 to 1382° F) -200 to 760° C (-328 to 1400° F) -200 to 1250° C (-328 to 2282° F) -200 to 1300° C (-328 to 2372° F) -0 to 1768° C (-32 to 3214° F) -0 to 1768° C (-32 to 3214° F) -200 to 400° C (-328 to 752° F) |
-50 to 506° C 2000 to 18200° C (3000 to 32760° F) -2000 to 7500° C (-3280 to 13820° F) -2000 to 7600° C (-3280 to 14000° F) -2000 to 12500° C (-3280 to 22820° F) -2000 to 13000° C (-3280 to 23720° F) -0 to 17680° C (-32 to 32140F) -0 to 17680° C (-32 to 32140° F) -200
to 4000°
C (-3280 to 7520°
F |
IO-PT4 |
|
-50° to 460°C |
-500° to 4600°C |