HMI

 

Type

Description

 

Error

 This application contains more than 255 Displays.

 

Error

   VariableXXX is not supported: (V290 does not support List Keypad Entry Variables.)

 

Error

 Shape Graph, not supported by V120-12.

 

Error

 Moving Image, not supported by V120-12.

 

Error

   VariableXXX is not supported: (V120-12 does not support Text Keypad Entry Variables.)

 

Error

 This Display contains more than 24 Variables.

 

Error

 UTC variable: " VariableXXX " - Vector length exceeds operand range.

 

Error

 The variable: " VariableXXX " contains more then 255 elements.

 

Error

 The Shape Graph variable: " VariableXXX " does not meet the minimum size requirement, 32 pixels per side.

 

Warning

 The variable: " VariableXXX " is NOT aligned to display grid; align to grid optimizes var display.

 

Warning

 The Numeric variable: " VariableXXX " is using a font with missing numeric charecters.

 

Warning

 The text field: XXX is too small to contain its data

 

Warning

 The variable: " VariableXXX " is too small to contain the variable data.

 

Error

 Error In Jump: X - No jump condition was set for : DisplayXXX

 

Error

 Error In Jump: X - No destination Display was defined for the Jump.

 

 

 

Ladder

 

Number

Type

Description

 

39

Error

Mismatched register types, Num To ASCII.

 

37

Error

NUM to ASCCI linked to Float, not supported by V120-12.

 

37

Error

 ElementXXX: not supported by V120-12, compatible with all other models

 

35

Error

Vector length exceeds operand range.

 

34

Error

Vector length value must be grater than 1.

 

33

Error

Missing Ethernet Com Init; Ethernet port will not be initialized.

 

40

Warning

Ethernet Card Init present, but Set PLC Name not in project.

 

44

Error

The transitional contact cannot function in this context.

 

38

Error

Illegal Element on interrupt subroutine – ElementXXX.

 

38

Error

Net is too complex for Interrupt subroutine.

 

38

Error

Timer cannot be included in Interrupt subroutine.

 

38

Error

Interrupt subroutine not supported by V120-12, compatible with all other models.

 

27

Error

Call to none existing Display.

 

41

Error

Track Events vector cannot exceed 256 MBs in length.

 

36

Warning

Configuration FB not included in Main Routine. Program may not run correctly.

 

32

Warning

Missing output Element - Net will not be compiled.

 

23

Error

The FB configuration used by this operation has been deleted.

 

42

Error

Main FB element (Config/Scan) cannot be in disabled net.

 

31

Error

This Element - Data Table link is no longer valid or no longer exists.

 

 

HW

 

Number

Type

Description

 

703

Error

Missing Snap-in I/O definition.

 

704

Error

 ???

 

700

 Warning

 Duplicate link for OperandTypeXXXOperandAddressXXX

 

701

 Warning

   ElementModelXXX , High speed input I <p>,<p> - counter mode must be filled

 

701

 Error

   ElementModelXXX, high speed output, All H.S Outputs must be linked to same Frequency operand.

 

705

 Error

 The defined hardware configuration does not support immediate input <p>

 

705

 Error

 The defined hardware configuration does not support immediate output <p>

 

705

 Error

 Immediate function cannot be linked to MB memory type.

 

705

 Error

 The defined hardware configuration does not support immediate analog output OprndPowerUpXXX

 

705

 Error

 The defined hardware configuration does not support immediate high speed input <p>,<p>

 

702

 Warning

 The defined hardware configuration does not support Input <p>

 

702

 Warning

 The defined hardware configuration does not support Output <p>

 

706

 Error

 Missing addresses for Load Cell element.

 

707

 Error

 Interrupt subroutine for HSC is not supported by the defined hardware configuration

 

 

 

Download

 

Number

Type

Description

 

987

 Warning

 Incompatible hardware configuration definitions: between project ( PCModelXXX) & PLC ( PLCModelXXX).

 

 

Function Blocks

 

Number

Type

Description

 

22

Error

Function Block requirements have exceeded RAM capacity.

 

21

Error

The legal number of configured FBs has been exceeded.

 

756

Error

The RT Files not exist for the Function Block FatherNameXXX.

 

756

Error

Topic (FB) overflow.

 

755

Error

The O/S in this PLC is outdated, and does not support the Function Block.